Call the front desk during business hours at (410) 862-0424.
Email us at frontdesk@openworksbmore.com. Please include your name, the machine you'd like to reserve, and the date(s) and times of the reservation(s).
Personal Protective Equipment (PPE):
• Sturdy, close-toed shoes must be worn at all times in all shops.
• Latex gloves should be worn when handling pretreat liquid.
For more information on shop safety visit Digital Textiles under "Safety."
Pull the filter out of the solution, but not out of the bottle.
Pull the drawer slightly out of the machine.
Press the clean button.
Once most of the pretreat is out of the tube, keep the clean button on and put your filter in the cleaning solution. (simple green & distilled water). Let it spray for about 30 seconds.
Stop the clean button.
Open the drawer completely.
Set the setting to level 5 bi direction and press the start button. This lets the cleaning solution coat the whole machine.
Now close the drawer completely and press the start button again.
Now that the machine is coated with the cleaning solution, pull the filter out of the cleaning solution but not out of the bottle.
Press the clean button to clear the tube of cleaning solution.
With the clean button still on, Pull the filter out of the cleaning solution and put it in Distilled Water bottle #2.
The tube should be completely clear of cleaning solution.
Stop the Clean cycle and press the start button to rinse the machine.
Repeat with the drawer open.
Open the machine and wipe everything down.
Wear gloves if you’re sensitive to chemicals.
If you notice a puddle of solution in the bottom of the machine, go to the back of the machine and wiggle the tube to the waste bucket.
Close the drawer and turn the machine off with the button on the front of the machine. Make sure the fan on the side of the machine is on.
You have successfully cleaned the pretreat machine!